Heating and Cooling Vacuum/Gas Stage MHCS600-XY
MicrOptik’s MHCS600-XY series are temperature controlled heating/cooling and vacuum/gas tight stages with an integrated solution for performing component-level electrical measurements. MHCS600-XY stages are ideal instruments for optical thermal microscopy and spectroscopy applications. It's perfect device for a precision temperature-controlled semiconductor testing. MHCS600-XY can be incorporated easily in any complex high-tech setup.
MicrOptik’s MHCS600-XY stages are developed for vacuum or/and gas tight applications with temperature range -190°C to 600°C. MHCS600-XY stages are supplied with a high precision MTDC600 programmable temperature controller. MTDC600 temperature controller can be operated by Software or Manually. It makes the system more adaptive and flexible. For applications below ambient temperature Liquid Nitrogen Cooling System LN2-SYS is provided.

Heating & Cooling Stage MHCS600-XY
MHCS600-XY Features:
- Vacuum or Gas Tight Environments
- Wide temperature range
- Programmable temperature controller
- High precision and high resolution temperature measurement and control
- Software or Manual control
- XY sample positioning
- 3 Lemo connectors x 4 pins
- Vacuum port, gas port, vacuumed 4/6 or 8 pins electrical feedthrough
- Water cooling frame
MTDC600 Temperature Controller and Software
The MTDC600 is a high performance temperature controller with resolution and accuracy 0.1°C. The controller MTDC600 has a built-in power supply and can be controlled manually or through a USB2.0 communication port. Software provides a convenient platform for all possible experiments. PID parameters, temperature limits and control essentials can be easily selected through the relevant menus.
MHCS600-XY Technical Specification
| Temperature Range | -190°C to 600°C (below ambient operation; requires optional cooling accessory) |
| Temperature Resolution | 0.1°C with MTDC600 Temperature Controller |
| Temperature Stability | ±0.1°C at 100°C with MTDC600 Temperature Controller |
| Minimum Heating Rate | 0.1°C/min |
| Maximum heating Rate | 150°C/min |
| Maximum cooling Rate | 60°C/min |
| Temperature Control Method | Switching PID-PID |
| Temperature Control Sensor | RTD |
| Heating/cooling Block | Silver |
| Thermal Stage Operating Working Distance | 13.1mm |
| Thermal Stage Operating Condencer Distance | 15.6mm |
| Sample Area | 40mmx40mm |
| Sample Chamber Height | 12.1mm |
| Windows Material | ZnSe |
| Sample Viewing Aperture | 30mm top window 2mm for transmitted light (larger aperture optional) |
| Sample Positioning | XY positioning system for remote manipulation in closed chambers |
| Electrical Feed-throught | 3 Lemo connectors x 4 pins |
| Vacuum/gas tight port | KF40 (other per request) |
System Configuration